PO_Dump_INP
Save entire model as INP file
Inputs
model [Required]
A Honeybee Model object to be written to a INP file.
name [Default]
A name for the file to which the honeybee objects will be written. If unspecified, it will be derived from the model identifier.
folder [Default]
An optional directory into which the honeybee objects will be written. The default is set to the default simulation folder.
hvac_mapping [Default]
An optional input to group rooms for HVAC mapping. Valid options are:
room
,story
,model
, andassigned-hvac
. The default is set to 'story'.exclude_InWalls []
Set to "True" to exclude all interior walls. The default is set to False to include all interior walls.
exclude_InCeilings []
Set to "True" to exclude all interior ceilings. The default is set to False to include all interior ceilings.
switch_statements [Optional]
Set to "True" to use switch statements. The default is set to False.
dump [Required]
Set to "True" to save the honeybee model to a INP file.
Outputs
inp
The location of the file where the INP file is saved.